Biến tần Omron 3G3JX- A2007

Đại lý biến tần omron, nhà phân phối biến tần omron

Inverter Usage
conditions
Regenerative
braking unit
Braking resistor Con-
nec-
tion
con-
figu-
ration
Restrictions
Volt-
age
Max.
appli-
cable
motor
ca-
pacity
(kW)
Mode %ED
*1
(%)
Ap-
proxi-
mate
braking
torque
(% *2)
Model Num-
ber
of
units
Model Num-
ber
of
units
Allowa-
ble
contin-
uous
braking
time
(s)
Min.
con-
nect-
able
resis-
tance
(Ω)
200-V
Class
0.2 3G3JX-
A2002
3G3JX-
AE002
3.0% 220% 3G3AX-
RBU21
1 Built-in Inverter 10 10 17
10.0% 220% 1 10 10 17
0.4 3G3JX-
A2004
3G3JX-
AE004
3.0% 220% 3G3AX-
RBU21
1 Built-in Inverter 10 10 17
10.0% 220% 1 10 10 17
0.75 3G3JX-
A2007
3G3JX-
AE007
3.0% 120% 3G3AX-
RBU21
1 Built-in Inverter 10 10 17
10.0% 120% 1 10 10 17
1.5 3G3JX-
A2015
3G3JX-
AE015
2.5% 110% 3G3AX-
RBU21 *3
1 3G3AX-RBA1202 1 11 12 17
10.0% 215% 1 3G3AX-RBC4001 1 11 10 17
2.2 3G3JX-
A2022
3G3JX-
AE022
3.0% 150% 3G3AX-
RBU21 *3
1 3G3AX-RBB3001 1 11 30 17
10.0% 150% 1 3G3AX-RBC4001 1 11 10 17
3.7 3G3JX-
A2037
3.0% 125% 3G3AX-
RBU21 *3
1 3G3AX-RBB4001 1 11 20 17
10.0% 125% 1 3G3AX-RBC6001 1 11 10 17
5.5 3G3JX-
A2055
3.0% 120% 3G3AX-
RBU21 *3
1 3G3AX-RBB3001 2 12 30 17
10.0% 120% 1 3G3AX-RBC4001 2 12 10 17
7.5 3G3JX-
A2075
3.0% 125% 3G3AX-
RBU21 *3
1 3G3AX-RBB4001 2 12 20 17
10.0% 130% 1 3G3AX-RBC12001 1 11 10 17
400-V
Class
0.4 3G3JX-
A4004
3.0% 220% 3G3AX-
RBU41 *3
1 Built-in Inverter 21 10 34
10.0% 220% 1 21 10 34
0.75 3G3JX-
A4007
3.0% 220% 3G3AX-
RBU41 *3
1 Built-in Inverter 21 10 34
10.0% 220% 1 21 10 34
1.5 3G3JX-
A4015
3.0% 120% 3G3AX-
RBU41 *3
1 Built-in Inverter 21 10 34
10.0% 120% 1 21 10 34
2.2 3G3JX-
A4022
2.5% 150% 3G3AX-
RBU41 *3
1 3G3AX-RBA1202 2 13 12 34
10.0% 220% 1 3G3AX-RBC4001 2 13 10 34
3.7 3G3JX-
A4037
3.0% 175% 3G3AX-
RBU41 *3
1 3G3AX-RBB3001 2 13 30 34
10.0% 175% 1 3G3AX-RBC4001 2 13 10 34
5.5 3G3JX-
A4055
3.0% 120% 3G3AX-
RBU41 *3
1 3G3AX-RBB3001 2 13 30 34
10.0% 120% 1 3G3AX-RBC4001 2 13 10 34
7.5 3G3JX-
A4075
3.0% 125% 3G3AX-
RBU41 *3
1 3G3AX-RBB4001 2 13 20 34
10.0% 125% 1 3G3AX-RBC6001 2 13 10 34